Installation is carried out on the ceiling and its guaranteed detection coverage is 360° with a radius of up to 5.5 m at 3.5 m mounting height.
Resistance to false alarms is adjustable in two levels.
The detector has an impulse response and occupys one position in the system.
Certified ceiling detector accessories are a mounting pad (PLV-P-ST) that can be used for wireless detectors to zoom out the antenna from the mounting surface and thus potentially improve range.
Specifications
Power supply: up to 2x CR123A (3 V/1500 mAh)
Lifetime: 1x CR123A 2 years/2x CR123A 4 years
Low battery voltage: <2.4 V
Communication frequency: 868.1 MHz
Communication range: approx. 300 m (free terrain)
Recommended installation height: 2.5 -3.5 m above floor level
Detection angle/detection coverage: 360°/11 m (installation height 3.5 m)
Dimensions: ∅ 125 x 40 mm
Classification: grade 2 according to EN 50131-1,
Environment according to EN 50131-1 II. indoor general
Operating temperature range: -10 °C to +40 °C
Also meets STN EN 50130-4, STN EN 55022