CK-13-AB Medium intensity aerial obstacle light
Widely used in various areas of aviation, at civil airports and in unobstructed airspace, helipads, iron towers, chimneys, ports, wind farms, bridge and urban high-rise buildings.
Widely used in various areas of aviation, at civil airports and in unobstructed airspace, helipads, iron towers, chimneys, ports, wind farms, bridge and urban high-rise buildings.
Safe shopping
Fast delivery
Hassle-free return of goods
450 tax excl.
The use:
Widely used in various areas of aviation, at civil airports and in unobstructed airspace, helipads, iron towers, chimneys, ports, wind farms, bridge and urban high-rise buildings
buildings where air traffic warning is required.
It is usually used over 45 m and less than 150 m of buildings, it can be used alone, it can also be used with medium OBL type B and low intensity OBL type B together
Features:
Installation and setup:
a) Installation
b) Installation drawing
Common installation methods for this product are two kinds of vertical installation methods and side vertical installation methods (see the figure below).
For steel structures, perimeter walls, fans, etc. It is necessary to design the support brackets according to the specific structure of the installation position.
Wiring:
Distinguish 1) The connector distinguishes: The obstruction light has a 4-core cable in which the brown and black lines are the power lines (AC220V or AC110V), the brown is the live line (L), the black is the Null Line (N), the blue is the Signal Line ( X) and yellow green is the Earth line (E).
(2) Winding instructions:
a. When connecting one light unit, only the brown live line (L), the black zero line (N) and the yellow-green ground line (E) need be connected. The blue synchronized signal does not need to be connected.
b. When connecting more than one unit light, all lines must be connected so that the lights can flash in sync.
Maintenance:
The shade needs to be cleaned every six months or one anniversary. Cleaning requires a soft cleaning tool. Cannot be used on a solid cleaning tool
Avoid scratching the bulb cover (plastic material).
Packing / storage:
Warning: